Riptide

subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link | subglobal1 link
subglobal2 link | subglobal2 link | subglobal2 link | subglobal2 link | subglobal2 link | subglobal2 link | subglobal2 link
subglobal3 link | subglobal3 link | subglobal3 link | subglobal3 link | subglobal3 link | subglobal3 link | subglobal3 link
subglobal4 link | subglobal4 link | subglobal4 link | subglobal4 link | subglobal4 link | subglobal4 link | subglobal4 link
subglobal5 link | subglobal5 link | subglobal5 link | subglobal5 link | subglobal5 link | subglobal5 link | subglobal5 link
subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link | subglobal6 link
subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link
subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link

Riptide 5% Pyrethrin ULV Mosquito Misting Systems

riptide mosquito misting

 

Save $120.00 per bottle

Why pay $260.00 for a service refill, when you can DIY in a few of minutes for $$$ less..

Drum or MistAway Gen III cartridge systems

Riptide 4 x 64oz @ $139.99 each

• Riptide Waterbased Pyrethrin ULV is specially designed to deliver fast knockdown and kill of mosquitoes.
• Riptide has an optimized ratio of pyrethrum and synergist (1:5)
• Riptide’s polymeric water-based technology is not harmful to landscape plants
• Riptide is designed for stability in fixed systems

 

Try the NEW, MORE POWERFUL SECTOR (10% Permethrin) for Mosquito Misting. SECTOR is ideal for high mosquito populations or hard to kill insects such as gnats, biting midges and no-see-ums. Sectors unique formula combines Permethrin with the synergist PBO for a higher level of performance. SECTOR will work in all mosquito misting systems.

Click on SECTOR to go to the SECTOR store.

 

Usage

• Control mosquitoes
• Reclaim backyards or patios
• Attain more cost-effective mosquito control

Riptide Pyrethrum

 

 

 

 

 


Riptide MGK

 

Mosquito Misting

Mosquito Misting USA, Inc

www.MosquitoMistingUSA.com

 

 

 

.

Riptide Pyrethrum

Time To Winterize

The most important thing to remember with winterization is that as much fluid as possible needs to be evacuated from the system and nozzle circuit. This action will ensure that, in the event of a hard freeze, any trapped fluid has room to expand as it freezes without placing pressure on a component. It's also important to flush the system and nozzle circuit with as much fresh water as possible to eliminate any lingering chemical residue. While some installers in colder climates choose to use potable anti-freeze or windshield washer fluid to flush the system and nozzle circuit, the most important thing is to remove as much fluid from the system as possible. Now is also a good time to clean and inspect the suction filters on the unit. These instructions will apply to whether you are using Riptide, Hudropy 300 or Summer Frost
 
Please note that in 2008 MistAway Systems, Inc. Will not warranty any equipment that has been damaged as a result of a lack of or improper winterization.
 
Drum Based Systems

  • Flush pump (and agitation valve if equipped) with clean water:
    • Fill 10 gallon bucket with fresh water and position next to unit.
    • Lift drum lid (with mounted assembly) from drum and rotate/reposition so that pump intake line (and agitation j-tube if equipped) are submerged inside 10 gallon bucket. 
    • Activate an extended manual mist.  The mist cycle will further flush the pump and nozzle circuit, and the agitation cycle will flush the agitation valve (on Gen 1.3 systems so equipped) 
    • Remove intake line (and agitation j-tube if equipped) from bucket, disconnect nozzle circuit line, and activate a dry (I.e., suction line not in any fluid) manual mist to clear water from valve and pump. 
    • Reposition drum lid and assembly back on drum.
  • Unplug unit and wrap power cord around assembly.
  • Replace waterproof cover.

Tankless Systems

These instructions will apply to whether you are using Riptide, Hudropy 300 or Summer Frost

  • Flush coupler, dosing pump and insecticide flow line.
    • Screw Smart Cap or PRO-CAP onto a vented bottle filled with either clean water or potable water anti-freeze.
    • Execute a MANUAL CHARGE to activate the dosing pump.  Navigate to INS in MAINTENANCE Menu.  On Gen III, press all three arrow buttons simultaneously for a period of  5 seconds.  On Gen II, hold down the SELECT knob and the AUTO ON/OFF button simultaneously for 5 seconds. 
    • DOSE and a countdown will be displayed.  The unit will run the dosing pump for an extended period, flushing insecticide out of the pump and line.  You may interrupt the dose after 2 minutes.
    • Remove Smart Cap from bottle and snap the cap alone into Smart Coupler.  Execute a MANUAL CHARGE to pump air through and thus evacuate fluid from insecticide flow line.  Interrupt DOSE after 2 minutes.
  • Flush batch tank, pump and agitation valve with clean water.
    • Drain the batch tank. (MAINTENANCE Menu, DRN, Press Green arrow button (Gen III) or SELECT knob (Gen II) for 5 seconds.)  Press STOP when pressure falls. You may wish to lift the right front corner of the system slightly to help evacuate as much fluid as possible from the mixing vessel.
    • Run Inspect to flush the batch tank and nozzle circuit (MAINTENANCE Menu, INS, Press Green arrow button or SELECT knob for 5 seconds.)  If zone kit, run INS1 and INS2 to flush both nozzle circuits.
    • Run DRN to drain the batch tank again.
  • Evacuate remaining fluid from inlet water line and pump discharge line. 
    • Disconnect nozzle circuit from unit.
    • Disconnect water supply line.
    • On Gen III, use WINT function to hold inlet supply valve and agitation valve open for 30 seconds to allow any remaining trapped fluid to drain. WINT is in the MAINTENANCE Menu.  Hold Green arrow button for 5 seconds to trigger.
    • On Gen II, use the inspect (INS) function to open the inlet supply valve (system will think it is trying to fill the tank with water).
    • With the valves open (Gen III displaying OPEN, Gen II displaying FILL), lift the left (Gen III) or right (Gen II) side of unit about 4 inches to let water run out of valve. You may also wish to blow some air into the water fitting (with the valves open) to ensure no water remains trapped in the unit.
  • Unplug unit, coil power cord and stow under unit.

 